How
do I set up a conference call with a Konftel telephone?
If
three parties wish to have a conference call, it can be done with
the help of the three party conference call function in the
telephone network/PBX. If more than three parties are to engage in
the conference call, you can use a conference call service provided
by a service provider.
How
do I connect a conference call with my Konftel 100, 200, 200W or
200NI?
Do
as follows:
* Call the first participant. Wait for an answer.
* Then press R (F in America) and wait for a new dialling tone.
* Call the second participant. Wait for an answer.
* Press R (F in America) then 3. Three participants are now
connected in a conference call.
To connect more than 3 participants (provided that the PBX supports
it) continue as follows:
* Press R (F in America) again. Wait for a new dialling tone.
* Call the next participant. Wait for an answer.
* Finish with R (F in America) followed by 3.
Repeat this for as many participants as the PBX supports.
Note that 3-party calls do not work with certain PBX's.
My
Konftel is connected to a switchboard. I follow the instructions for
multiparty calls, but it doesn't work. What is wrong?
1. Your PBX does not support mulipart
calls. Contact your PBX reseller for upgrading.
2. Your PBX needs another comand than R3 to connect more parties,
read the table below.
3. You need another commando, read the table below.
| Brand
|
Type |
Instead of R3, press: |
Instruktion |
| Ericsson |
MD 110 |
3 |
|
| Euro |
Generis |
R63 |
|
| Philips |
Sopho IS3000 |
|
>> |
| Siemens HiCom |
Office |
*5 |
|
How
do I connect a conference call with my Konftel 50, 60W or 100/D, via
my MD 110-switchboard, for example?
I have no R
button.
First connect the conference call with your system telephone. Turn
on the Konftel when all parties are connected.
I
press the R/F button but don't get a new dial tone when I want to
call next participant. What's wrong?
You have to change the default R pulse/Flash time. It can
vary from country to country but also depend on the PBX to which
Konftel is connected.
Do as follows for Konftel 200 o r 200NI:
* Press MENU.
* Select Special Settings menu (tools).
* Press OK.
* Choose R/Flash function (up/down).
* Press OK.
* Enter the value for the R-pulse/Flash time as the table below:
| Value: |
Time: |
PBX/country: |
| R1 |
65 ms |
Ericsson MD110 |
| R2 |
100 ms |
Scandinavia, Europe |
| R3 |
150 ms |
Reserve |
| R4 |
270 ms |
Germany, France, Israel |
| R5 |
600 ms |
USA |
| R6 |
80 ms |
Siemens HiPath |
* Press OK to save the settings and exit.
(Please note that the R6 function only exist on some products
manufactured after Oct. 2005)
Do as
follows for Konftel 100:
* Hold dow the R/F key for three seconds until the green LEDs flash
and you hear three short beeps.
* Enter the value for the R-pulse/Flash time as the table below:
| Value: |
Time: |
PBS/country: |
| 1 - R function |
65 ms |
Ericsson MD110 |
| 2 - R function |
100 ms |
Scandinavia, Europe |
| 3 - R function |
150 ms |
Reserve |
| 4 - R function |
270 ms |
Germany, France, Israel |
| 5 - R function |
600 ms |
USA |
* Press OK to save
the settings and exit. |
|
|
 |
|